Minor presentation fixes
continuous-integration/drone/push Build is passing Details

main
Thomas Quinot 24 hours ago
parent 5b572b9ac6
commit 493330ae01

@ -8,22 +8,25 @@ categories:
## Where we are: funny L600 ## Where we are: funny L600
I captured more traces showing voltage before L600 (i.e. at the net labeled "8" from the power supply in Sams Computer Facts) and after it (i.e. at the CPU's Vcc pin), also recording the min and max voltage. I captured more traces showing voltage before L600 (i.e. at the net labeled "8" from the power supply in Sams Computer Facts) (<span style="background-color: #f8fc00;">yellow</span>) and after it (i.e. at the CPU's Vcc pin) (<span style="background-color: #b800b8;">purple</span>), also recording the min and max voltage.
{% figure caption:"Old CPU" %} {% figure caption:"Old CPU, L600 not shunted (bad)" %}
![Old CPU, L600 not shunted (bad)](assets/TI-resto/20250703-oldCPU-L600.png) ![Old CPU, L600 not shunted (bad)](assets/TI-resto/20250703-oldCPU-L600.png)
{% endfigure %}
{% figure caption:"Old CPU, L600 shunted (OK)" %}
![Old CPU, L600 shunted (OK)](assets/TI-resto/20250703-oldCPU-shuntL600.png) ![Old CPU, L600 shunted (OK)](assets/TI-resto/20250703-oldCPU-shuntL600.png)
{% endfigure %} {% endfigure %}
We are seeing: We are seeing:
* very large voltage variations downstream of L600 when it's not shunted * very large voltage variations downstream of L600 when it's not shunted
* interstingly, slightly different readings on the two probes even when shunted with a wire :frown: * interstingly, slightly different readings on the two probes even when shunted with a wire 🤔
## Replacing the CPU & a provisional conclusion ## Replacing the CPU & a provisional conclusion
The hypothesis at this stage is a marginal CPU that draws a little too much current, so I'm trying to replace it with another one from eBay. The hypothesis at this stage is a marginal CPU that draws a little too much current, so I'm trying to replace it with another one from eBay.
{% figure caption:"New CPU" %} {% figure caption:"New CPU -- it works!" %}
![New CPU, L600 not shunted (OK)](assets/TI-resto/20250703-newCPU.png) ![New CPU, L600 not shunted (OK)](assets/TI-resto/20250703-newCPU.png)
{% endfigure %} {% endfigure %}